Clinical Calculators

Bowel Preparation Quality (BBPS) & Repeat Interval

Score the right, transverse and left colon on the Boston Bowel Preparation Scale and see whether the published thresholds call the preparation adequate, which segment is the one that fails, and the repeat interval the 2025 US Multi-Society Task Force attaches to an inadequate preparation for that indication — with the exact wording and evidence grade behind every number, plus the split-dose evidence the same document rests on.

1 · Score each segment

Score on withdrawal, after all washing and suctioning are finished. Each segment scores 0–3 and the three add up to a total out of 9. If a segment was never reached, mark it so — a segment you did not see is not a segment you can score.

Right colon — Caecum and ascending colon
Transverse colon — Transverse colon including the hepatic and splenic flexures
Left colon — Descending colon, sigmoid colon and rectum
2 · Why the colonoscopy was done
The 2025 USMSTF recommendation sets a different urgency for a screening or surveillance examination than for one done to chase an abnormal non-colonoscopic screening test.
3 · Examination context
4 · Your unit’s adequacy rate (optional)

Both task forces now ask endoscopy units and individual endoscopists to track this. Cancellations made for preparation-related reasons before the scope goes in belong in the denominator.

Preparation verdict
Every published threshold for “adequate”, side by side

The rule this tool applies. Adequate when every segment scores at least 2, which also makes the total at least 6. Any segment scoring 0 or 1 makes the preparation inadequate whatever the total is. ACG/ASGE 2024 quality indicator 2, whose wording is explicit at segment level; concordant with USMSTF 2025 and with the conclusion of Clark 2016.

WhoWhat it saysGrade and provenance
USMSTF 2025
What the word means
“We recommend the term “adequate bowel preparation” be used to indicate that standard screening or surveillance intervals can be assigned based on the findings of the colonoscopy.”
Strong recommendation, moderate-quality evidence
USMSTF 2025, Assessing Bowel Preparation · 2025-04
USMSTF 2025
Numeric threshold
“One prospective study conducted in male veterans observed that patients with BBPS segment scores of 2 or 3 for all colonic segments had an adequate bowel preparation as defined by the ability to detect adenomas larger than 5 mm. These data helped to further validate the BBPS and also support a recommendation to consider a BBPS score less than 6 due to any segment score less than 2 as inadequate, requiring a repeat colonoscopy as soon as feasible within 12 months.”
Narrative rationale supporting the graded rescheduling recommendation
USMSTF 2025, Assessing Bowel Preparation, discussing Clark 2016 · 2025-04
ACG/ASGE 2024
Numeric threshold
“Percentage of patients undergoing colonoscopy with adequate bowel preparation, preferably defined as Boston Bowel Preparation Scale score at least 2 in each of 3 colon segments or by description of the preparation as excellent, good, or adequate. The recommended screening or surveillance interval should be consistent with US Multi-Society Task Force recommendations.”
Strength of recommendation 1C; process measure; performance target at least 90 percent; priority indicator
ACG/ASGE 2024, Table 3 and quality indicator 2 narrative · 2024-09
Calderwood 2014
Numeric threshold
“A total BBPS score of at least 6 and/or all segment scores of at least 2 provides a standardized definition of “adequate for 10-year follow-up”.”
Cross-sectional observational analysis of 2,516 normal screening colonoscopies performed by 74 endoscopists at 36 practices in the Clinical Outcomes Research Initiative registry
Calderwood 2014 · 2014-08
Clark 2016
Numeric threshold
“Patients with BBPS scores of 2 or 3 for all colon segments have adequate bowel preparation for the detection of adenomas larger than 5 mm.”
Tandem colonoscopy study: 438 men, 1,161 colon segments, repeat examination within 60 days by a different blinded endoscopist. Adjusted proportion with missed adenomas larger than 5 mm was 5.2 percent for segments scored 2 versus 5.6 percent for segments scored 3, meeting a prespecified non-inferiority margin of 5 percent.
Clark 2016 · 2016-02
ESGE
Numeric threshold
“ESGE states that standard guideline recommendations for surveillance intervals apply only to patients with adequate bowel preparation, defined as Boston Bowel Preparation Scale at least 6, Ottawa Scale at most 7, or Aronchick Scale excellent, good or fair.”
Stated as the adequacy premise attached to the ESGE post-polypectomy surveillance recommendations
ESGE post-polypectomy surveillance guideline 2020, section on inadequate bowel preparation · 2020
USMSTF 2020
Functional definition
“Adequate bowel preparation: bowel preparation adequate for visualization of polyps larger than 5 mm in size. The surveillance intervals in that document assume an examination complete to the caecum with an adequate preparation, performed by a colonoscopist with an adequate adenoma detection rate and attention to complete polyp excision.”
Definition table plus stated colonoscopy quality assumptions
USMSTF 2020, Table 3 definitions and Colonoscopy quality assumptions · 2020-03
The scale itself

Each of three colon segments is scored 0 to 3 and the three segment scores are summed, so the total runs from 0 (unprepared colon) to 9. Segment scores are assigned after all cleansing manoeuvres are completed by the endoscopist. (Lai 2009, as of 2009-03).

ScoreShort formPublished wording
0UnpreparedUnprepared colon segment with mucosa not seen because of solid stool that cannot be cleared.
1Partly seenPortion of mucosa of the colon segment seen, but other areas of the colon segment not well seen because of staining, residual stool and/or opaque liquid.
2Seen well, minor residueMinor amount of residual staining, small fragments of stool and/or opaque liquid, but mucosa of colon segment seen well.
3Entirely seenEntire mucosa of colon segment seen well with no residual staining, small fragments of stool or opaque liquid.
“We recommend bowel preparation quality be assessed after all washing and suctioning have been completed, using reliably understood descriptors that communicate the adequacy of the preparation.” (Strong recommendation, moderate-quality evidence)
Source: USMSTF 2025, Assessing Bowel Preparation
How well it holds upValueSource
Interobserver agreement, total score (development study, 633 colonoscopies, 22 clinicians)Intraclass correlation coefficient 0.74 (95% predictive interval 0.67-0.80)Lai 2009 · 2009-03
Intraobserver agreement (development study)Weighted kappa 0.77Lai 2009 as reported in Kastenberg 2018 · 2018-07
Interrater reliability (comprehensive validation, 983 colonoscopies)Intraclass correlation coefficient 0.91Calderwood 2010 · 2010-10
Intrarater reliability (comprehensive validation)Weighted kappa 0.78 (95% CI 0.73-0.84)Calderwood 2010 · 2010-10
Standing among competing scalesOne large systematic review of various bowel preparation scales concluded that the Boston Bowel Preparation Scale was the most reliable and thoroughly validated.USMSTF 2025, citing Kastenberg 2018 · 2025-04
Why the guideline prefers itBecause it uses scores and explicit descriptions of what the scores mean, the Boston Bowel Preparation Scale is preferred. Further, the Boston Bowel Preparation Scale is specifically designed for use after completion of intraprocedural bowel cleaning, which is the most clinically relevant time point to assess cleansing quality.ACG/ASGE 2024 · 2024-09
Split dosing — the evidence the recommendation rests on
WhoRecommendationGrade
USMSTF 2025“We recommend a split-dose administration of bowel preparation purgatives for all patients, regardless of high-volume or low-volume preparation.”
Strong recommendation, high-quality evidence
USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
USMSTF 2025“We recommend that a same-day regimen is an acceptable alternative to split dosing for individuals undergoing an afternoon colonoscopy.”
Strong recommendation, high-quality evidence
USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
USMSTF 2025“We suggest that a same-day regimen is an inferior alternative to split dosing for individuals undergoing a morning colonoscopy.”
Weak recommendation, low-quality evidence
USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
USMSTF 2025“For individuals using a split-dose regimen for colonoscopy preparation, we recommend the consumption of the second portion begin 4-6 hours before the time of colonoscopy and be completed at least 2 hours before the procedure start.”
Strong recommendation, moderate-quality evidence
USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
ESGE 2019“ESGE recommends split-dose bowel preparation for elective colonoscopy.”
Strong recommendation, high quality evidence
ESGE 2019, Main Recommendations · 2019-08
ESGE 2019“ESGE recommends, for patients undergoing afternoon colonoscopy, a same-day bowel preparation as an acceptable alternative to split dosing.”
Strong recommendation, high quality evidence
ESGE 2019, Main Recommendations · 2019-08
ESGE 2019“ESGE recommends to start the last dose of bowel preparation within 5 hours of colonoscopy, and to complete it at least 2 hours before the beginning of the procedure.”
Strong recommendation, moderate quality evidence
ESGE 2019, Main Recommendations · 2019-08
The two task forces word the runway differently.
USMSTF 2025. Begin the second portion 4-6 hours before the time of colonoscopy and complete it at least 2 hours before the procedure start (strong recommendation, moderate-quality evidence).
ESGE 2019. Start the last dose within 5 hours of colonoscopy and complete it at least 2 hours before the beginning of the procedure (strong recommendation, moderate quality evidence).

Both set the same floor of at least 2 hours before the start. They differ at the far end: USMSTF names a 4-to-6-hour window for starting the second portion, ESGE caps the start at 5 hours. A start 5.5 to 6 hours out satisfies USMSTF and not ESGE. Neither figure is averaged here; both are shown as written.
Source: USMSTF 2025 and ESGE 2019 recommendation boxes · as of 2025-04
What was measuredResult as publishedSource
Split-dose versus day-before, quality of cleansingOdds ratio 2.51 (95 percent CI 1.86-3.39) for excellent or good cleansing, from 47 randomised trials and 13,487 patientsMartel 2015, reproduced in the ESGE 2019 text · 2015-07
Same comparison restricted to polyethylene glycolOdds ratio 2.60 (95 percent CI 1.46-4.63)Martel 2015, reproduced in the ESGE 2019 text · 2015-07
Same comparison restricted to sodium phosphateOdds ratio 9.34 (95 percent CI 2.12-41.11)Martel 2015, reproduced in the ESGE 2019 text · 2015-07
Same comparison restricted to sodium picosulfateOdds ratio 3.54 (95 percent CI 1.95-6.45)Martel 2015, reproduced in the ESGE 2019 text · 2015-07
Willingness to repeat the preparationOdds ratio 1.90 (95 percent CI 1.05-3.46) favouring split-doseMartel 2015, reproduced in the ESGE 2019 text · 2015-07
Detection, split-dose versus day-prior 2 L PEG plus ascorbate (randomised trial)Adenoma detection per colonoscopy 53.0 versus 40.9 percent; advanced adenoma detection per colonoscopy 26.4 versus 20.0 percent; adenomas per patient 1.15 versus 0.8 (p less than 0.001); advanced adenomas per patient 0.36 versus 0.22 (p less than 0.001)USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
How fast the split-dose advantage decays with runway timeIn a systematic review and meta-analysis of 29 randomised trials, the improvement from split dosing was maintained within 3 hours from the end of the purgative, progressively decreased after 4-5 hours, and was no longer present after 5 hoursUSMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
Every extra hour between last purgative and scope-in (non-split, day-prior regimens)Associated with a 10 percent decrease in the likelihood of a good or excellent preparationUSMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
Residual gastric fluid volume, split-dose versus day-prior (305 outpatients having EGD and colonoscopy, minimum 2-hour fast)11 mL versus 19 mL (p less than 0.001); pH 2 in both groupsUSMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04
What an inadequate preparation actually costs
MeasurePublished findingSource
Adenoma detection rate with an inadequate preparationA systematic review and meta-analysis of 11 studies and more than 55,000 colonoscopies found a 5 percent absolute lower adenoma detection rate and a 1 to 2 percent absolute lower advanced adenoma detection rate with inadequate preparations compared with adequate or intermediate preparations. The odds ratio for detecting at least one adenoma, high-quality versus low-quality preparation, was 1.41 (95 percent CI 1.21-1.64).Clark 2014, as reported in USMSTF 2025 · 2025-04
Adenoma miss rate after an inadequate preparationIn a single-centre study of 3,047 patients with an inadequate preparation, among the 216 who returned and achieved an adequate preparation, 83 previously unseen adenomas were found – an adenoma miss rate of 42 percent (95 percent CI 35-49) and an advanced adenoma miss rate of 27 percent (95 percent CI 17-41). Restricted to colonoscopies repeated within 1 year, the adenoma and advanced adenoma miss rates were 35 and 36 percent. No cancers were missed in that study.USMSTF 2025, Management of the Patient With an Inadequate and Nonsalvageable Bowel Preparation · 2025-04
Yield of the repeat examination after a suboptimal preparation following a positive FITIn 248 subjects with a positive faecal immunochemical test and a suboptimal preparation (BBPS segment score of 1 in at least one segment; segments scored 0 were excluded), the repeat colonoscopy at a mean of 352 days found an adenoma detection rate of 39 percent and an advanced adenoma detection rate of 15 percent.USMSTF 2025, Management of the Patient With an Inadequate and Nonsalvageable Bowel Preparation · 2025-04
How often the repeat is actually recommendedAmong 260,314 screening or surveillance colonoscopies with inadequate bowel preparation in the GIQuIC registry, only 32 percent were accompanied by a recommendation to repeat the procedure within a year. That rose to 52 percent when advanced adenomas or serrated polyps were found and to 61 percent when the endoscopist failed to reach the caecum.USMSTF 2025, Management of the Patient With an Inadequate and Nonsalvageable Bowel Preparation · 2025-04
Missed lesions when cleansing is inadequateA prospective observational study with repeat colonoscopy by a blinded endoscopist revealed a threefold higher miss rate for adenomas at least 5 mm in size when bowel cleansing was inadequate.ESGE 2019, Introduction · 2019-08
Segment-level signal, and its limitAmong segment pairs without polyps at the first colonoscopy (n = 601), segments with inadequate BBPS scores had a higher polyp detection rate at the second colonoscopy (10 versus 5 percent, p = 0.04); among segment pairs with polyps at the first colonoscopy (n = 154), advanced polyp detection at the second was 20 versus 4 percent (p = 0.03). In multivariable analysis, however, it was the presence of advanced polyps at the initial colonoscopy (adjusted odds ratio 3.5, 95 percent CI 1.1-10.8) and not an inadequate BBPS score (adjusted odds ratio 1.8, 95 percent CI 0.6-5.1) that independently predicted advanced polyps at the second examination.Kluge 2018 · 2018-03
The unit-level benchmark
WhoTargetStatement
USMSTF 202590%“We recommend an endoscopy unit-level and individual endoscopist-level bowel preparation adequacy rate of at least 90 percent.”
Strong recommendation, moderate-quality evidence · USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04
USMSTF 2025—“We recommend routine tracking of the rate of adequate bowel preparations at the level of individual endoscopists and at the level of the endoscopy unit.”
Strong recommendation, moderate-quality evidence · USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04
ACG/ASGE 202490%“Rate of bowel preparation adequacy is a priority quality indicator with a performance target of at least 90 percent, measure type process, strength of recommendation 1C. To count toward meeting the 90 percent compliance target, the recommended follow-up interval must be consistent with US MSTF post-polypectomy or post-cancer resection surveillance recommendations.”
1C, process measure, priority indicator · ACG/ASGE 2024, Table 3 and quality indicator 2 · as of 2024-09
ESGE90%“A minimum standard of at least 90 percent for adequate bowel preparation, assessed using validated scales, has been recommended by the Quality Committee of the European Society of Gastrointestinal Endoscopy.”
ESGE performance measure, quoted in the ESGE 2019 introduction · ESGE 2019, Introduction · as of 2019-08
USMSTF 2014 (superseded)85%“The US MSTF recommended in 2014 that at least 85 percent of outpatient colonoscopies should be accompanied by an adequate bowel preparation.”
Superseded by the 90 percent target in ACG/ASGE 2024 and USMSTF 2025 · ACG/ASGE 2024, Rate of bowel preparation adequacy · as of 2014
Key Concept (ungraded). Individuals whose colonoscopies are cancelled for presumed inadequate preparation (i.e., before colonoscope insertion) should be included when calculating both endoscopy unit and endoscopist-level bowel preparation adequacy rates.
Source: USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04
Registry benchmark. In a GIQuIC consortium report analysing 3,773,519 screening and surveillance colonoscopies between 2010 and 2017, inadequate bowel preparation was reported in 5.3 percent. The definition of adequacy is not standardised across the more than 700 participating practices.
Source: USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04
Registry benchmark. In the Dutch Gastrointestinal Endoscopy Audit, unadjusted bowel preparation adequacy rates ranged between 90 and 99 percent across 51 endoscopy units; after case-mix adjustment for age, sex, ASA class and indication, several units’ performance changed significantly relative to the benchmark.
Source: USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04
Variation between endoscopists. In one retrospective study of ambulatory colonoscopies performed by 11 endoscopists at a university medical centre, the frequency of poor, unsatisfactory or fair bowel preparations ranged from 3 to 40 percent, mean 22 percent – a spread the guideline attributes to differing thresholds for calling a preparation adequate and differing effort spent on intraprocedural washing.
Source: USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04
Patient-related risk factors for an inadequate preparation

Representative odds ratio selected among the references cited by the guideline. The magnitudes are reproduced exactly as published.

Risk factorOdds ratio95% CI
Cirrhosis3.41.5–7.9
Parkinson disease3.21.2–9.3
Dementia3.01.2–7.5
Tricyclic antidepressant use2.01.4–2.9
Diabetes1.81.5–2.1
Opioid use1.71.4–2.1
Gastroparesis1.61.2–2.3
Previous colorectal surgery1.61.2–2.2
Lower level of education1.51.3–1.8
Body mass index above 30 kg/m21.51.2–1.8
Inpatient status1.51.1–2.1
Hypertension1.31.2–1.4
Tobacco use1.31.1–1.5
Constipation1.31.0–1.6
Medicaid versus private insurance1.31.1–1.6
Medicare versus private insurance1.21.1–1.3
Male sex1.21.1–1.3
Age above 651.11.1–1.2
Body mass index, each unit1.11.0–1.1
Why there is no total here. These odds ratios are shown individually and are deliberately NOT combined into a score. The guideline states that published predictive models based on these factors yield modest positive predictive values ranging from 29 to 41 percent, that use of predictive models has not yet been proven to improve bowel preparation quality, and that an efficient process to flag these patients during scheduling has not been demonstrated. It also notes that risk factors may have an additive effect, citing a study of 1,588 ambulatory colonoscopies in which the risk rose with the number of factors and plateaued at a 98 percent likelihood once 7 were present – but it publishes no weights, so none are invented here.
Source: USMSTF 2025, Table 4 and Bowel Preparation Regimen for Individuals at High Risk for Inadequate Bowel Preparation · as of 2025-04
Methodology, what is deliberately missing, and sources

Rule. Every score definition, threshold, interval, strength rating, benchmark and effect estimate in this file is copied from the named source. Nothing is estimated, averaged, interpolated or carried across from a similar entity. Where two authorities word the same rule differently, both are stored and both are shown attributed rather than reconciled. No drug dose appears unless the cited guideline itself states that dose, and where it does the recommendation grade travels with it.

Provenance. The published Gastroenterology and Gastrointestinal Endoscopy full texts of the 2025 USMSTF bowel preparation recommendations return HTTP 403 to automated fetching. The identical article text was read from the society-distributed PDF reprint (AGA Section, Gastroenterology April 2025, pages 798-829); page furniture in that PDF confirms the journal, volume, issue and page range. The 2024 ACG/ASGE quality indicators were read from the GIQuIC-hosted PDF of the American Journal of Gastroenterology article of record. Text extracted from the 2025 USMSTF and 2024 ACG/ASGE PDFs loses the greater-than-or-equal and less-than-or-equal glyphs in a few places. Where the surrounding sentence makes the relation unambiguous (for example an adequacy rate ‘of 90%’ in a sentence whose recommendation heading reads ‘of at least 90%’) the relation has been restored as ‘at least’. No numeric value was altered.

Built. 2026-08-01. Re-verify by. 2027-08-01. Re-verify at least annually, and immediately whenever the USMSTF revises its bowel preparation recommendations, the ACG/ASGE Quality Task Force revises the colonoscopy quality indicators, or ESGE updates its bowel preparation guideline.

Left out on purpose — the sources do not support it.

No conversion between BBPS and the Aronchick, Ottawa, Harefield or Chicago scales. No authority publishes a numeric crosswalk between these scales. They differ in direction (BBPS higher is better; Aronchick and Ottawa lower is better), in whether they score segments at all, and in whether scoring happens before or after washing and suctioning. ESGE enumerates BBPS at least 6, Ottawa at most 7 and Aronchick excellent/good/fair as parallel definitions of adequate, but that is a list of separately validated thresholds, not a conversion. Nothing is interpolated here.
No composite score predicting who will have an inadequate preparation. USMSTF 2025 reports that published predictive models yield positive predictive values of only 29 to 41 percent and that their use has not been shown to improve preparation quality. The individual odds ratios from Table 4 are displayed; no weighting scheme exists in the source, so none is invented.
No ranking or comparison of purgative products. USMSTF 2025 states: we do not recommend one bowel preparation purgative as superior to others (strong recommendation, high-quality evidence). A product league table would contradict the source.
No paediatric, inpatient or inflammatory-bowel-disease-specific thresholds. The 2025 USMSTF recommendations are written for ambulatory adults undergoing colonoscopy, and no society publishes a different BBPS adequacy threshold for children, inpatients or IBD surveillance. Inpatient status appears only as a risk factor for an inadequate preparation.
No post-polypectomy surveillance interval. When the preparation is adequate the interval depends on what was found, which is the subject of a separate document (USMSTF 2020) and a separate tool. This tool answers only whether the preparation permits a standard interval to be assigned at all.
No separate score for the rectum. The Boston Bowel Preparation Scale defines the left colon as the descending colon, sigmoid colon and rectum together. Splitting them would be an invented fourth segment.
No number of weeks for an alarm-symptom indication. USMSTF 2025 says a colonoscopy with adequate preparation should occur as soon as possible and that timing should consider the date of symptom onset. It states no interval, so none is shown.
No automated or image-based scoring. USMSTF 2025 notes that objective assessment using artificial intelligence platforms may become feasible but that currently an individual endoscopist must render a subjective determination. This tool records a human score; it does not produce one.
KeyCitationAs of / access
USMSTF 2025Jacobson BC, Anderson JC, Burke CA, Dominitz JA, Gross SA, May FP, Patel SG, Shaukat A, Robertson DJ. Gastroenterology 2025;168(4):798-829.
doi 10.1053/j.gastro.2025.02.002
Published simultaneously as Gastrointest Endosc 2025;101(4):702-732, doi 10.1016/j.gie.2025.02.010.
2025-04
Full PDF reprint read
ACG/ASGE 2024Rex DK, Anderson JC, Butterly LF, Day LW, Dominitz JA, Kaltenbach T, Ladabaum U, Levin TR, Shaukat A, Achkar JP, Farraye FA, Kane SV, Shaheen NJ. Am J Gastroenterol 2024;119(9):1754-1780.
doi 10.14309/ajg.0000000000002972
Published simultaneously in Gastrointestinal Endoscopy 2024;100(3):352-381.
2024-09
Full PDF read
ESGE 2019Hassan C, East J, Radaelli F, Spada C, Benamouzig R, Bisschops R, Bretthauer M, Dekker E, Dinis-Ribeiro M, Ferlitsch M, Fuccio L, Awadie H, Gralnek I, Jover R, Kaminski MF, Pellise M, Triantafyllou K, Vanella G, Mangas-Sanjuan C, Frazzoni L, van Hooft JE, Dumonceau JM. Endoscopy 2019;51(8):775-794.
doi 10.1055/a-0959-0505
2019-08
Full ESGE-hosted PDF read
USMSTF 2020Gupta S, Lieberman D, Anderson JC, Burke CA, Dominitz JA, Kaltenbach T, Robertson DJ, Shaukat A, Syngal S, Rex DK. Gastrointest Endosc 2020;91(3):463-485.
Published simultaneously in Gastroenterology 2020;158(4):1131-1153.
2020-03
Full ASGE-hosted PDF read
Lai 2009Lai EJ, Calderwood AH, Doros G, Fix OK, Jacobson BC. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc 2009;69(3 Pt 2):620-625.2009-03
PubMed Central full text (PMC2763922)
Calderwood 2010Calderwood AH, Jacobson BC. Comprehensive validation of the Boston Bowel Preparation Scale. Gastrointest Endosc 2010;72(4):686-692. PMID 20883845.2010-10
Publisher abstract of record
Calderwood 2014Calderwood AH, Schroy PC 3rd, Lieberman DA, Logan JR, Zurfluh M, Jacobson BC. Boston Bowel Preparation Scale scores provide a standardized definition of adequate for describing bowel cleanliness. Gastrointest Endosc 2014;80(2):269-276. PMID 24629422.2014-08
PubMed Central full text (PMC4104141)
Clark 2016Clark BT, Protiva P, Nagar A, Imaeda A, Ciarleglio MM, Deng Y, Laine L. Quantification of Adequate Bowel Preparation for Screening or Surveillance Colonoscopy in Men. Gastroenterology 2016;150(2):396-405.2016-02
Publisher abstract of record; the 2025 USMSTF document describes this study and its conclusion in its own words, which are quoted here
Clark 2014Clark BT, Rustagi T, Laine L. What level of bowel prep quality requires early repeat colonoscopy: systematic review and meta-analysis of the impact of preparation quality on adenoma detection rate. Am J Gastroenterol 2014;109(11):1714-1723.2014-11
Effect estimates quoted as reported inside the 2025 USMSTF document (reference 193)
Kluge 2018Kluge MA, Williams JL, Wu CK, Jacobson BC, Schroy PC 3rd, Lieberman DA, Calderwood AH. Inadequate Boston Bowel Preparation Scale scores predict the risk of missed neoplasia on the next colonoscopy. Gastrointest Endosc 2018;87(3):744-751. PMID 28648575.2018-03
Publisher abstract of record
Martel 2015Martel M, Barkun AN, Menard C, Restellini S, Kherad O, Vanasse A. Split-Dose Preparations Are Superior to Day-Before Bowel Cleansing Regimens: A Meta-analysis. Gastroenterology 2015;149(1):79-88. PMID 25863216.
doi 10.1053/j.gastro.2015.04.004
2015-07
Full abstract of record read; the same effect estimates are reproduced inside the ESGE 2019 PDF (reference 55), which was read directly
Kim 2024Kim J, Choi JM, Lee J, Han YM, Jin EH, Lim JH, Bae JH, Seo JY. Boston bowel preparation scale score 6 has more missed lesions compared with 7-9. Sci Rep 2024;14:1605.
doi 10.1038/s41598-024-52244-8
2024-01
PubMed Central full text (PMC10796329)
Kastenberg 2018Kastenberg D, Bertiger G, Brogadir S. Bowel preparation quality scales for colonoscopy. World J Gastroenterol 2018;24(26):2833-2843.
doi 10.3748/wjg.v24.i26.2833
2018-07
PubMed Central full text (PMC6048432)
Scope. Decision support for clinicians, not a prescription and not medical advice. Every threshold, interval and effect estimate shown carries the guideline or study it came from and the year of that document. The Boston Bowel Preparation Scale is an endoscopist’s observation: this tool records the score you enter and applies the published rule to it. It cannot see the colon, it does not know the indication beyond what you select, and it does not replace the judgement the guideline explicitly reserves to the endoscopist.
Was this calculator useful?