Bowel Preparation Quality (BBPS) & Repeat Interval
Score the right, transverse and left colon on the Boston Bowel Preparation Scale and see whether the published thresholds call the preparation adequate, which segment is the one that fails, and the repeat interval the 2025 US Multi-Society Task Force attaches to an inadequate preparation for that indication — with the exact wording and evidence grade behind every number, plus the split-dose evidence the same document rests on.
Score on withdrawal, after all washing and suctioning are finished. Each segment scores 0–3 and the three add up to a total out of 9. If a segment was never reached, mark it so — a segment you did not see is not a segment you can score.
Both task forces now ask endoscopy units and individual endoscopists to track this. Cancellations made for preparation-related reasons before the scope goes in belong in the denominator.
The rule this tool applies. Adequate when every segment scores at least 2, which also makes the total at least 6. Any segment scoring 0 or 1 makes the preparation inadequate whatever the total is. ACG/ASGE 2024 quality indicator 2, whose wording is explicit at segment level; concordant with USMSTF 2025 and with the conclusion of Clark 2016.
| Who | What it says | Grade and provenance |
|---|---|---|
| USMSTF 2025 What the word means | “We recommend the term “adequate bowel preparation” be used to indicate that standard screening or surveillance intervals can be assigned based on the findings of the colonoscopy.” | Strong recommendation, moderate-quality evidence USMSTF 2025, Assessing Bowel Preparation · 2025-04 |
| USMSTF 2025 Numeric threshold | “One prospective study conducted in male veterans observed that patients with BBPS segment scores of 2 or 3 for all colonic segments had an adequate bowel preparation as defined by the ability to detect adenomas larger than 5 mm. These data helped to further validate the BBPS and also support a recommendation to consider a BBPS score less than 6 due to any segment score less than 2 as inadequate, requiring a repeat colonoscopy as soon as feasible within 12 months.” | Narrative rationale supporting the graded rescheduling recommendation USMSTF 2025, Assessing Bowel Preparation, discussing Clark 2016 · 2025-04 |
| ACG/ASGE 2024 Numeric threshold | “Percentage of patients undergoing colonoscopy with adequate bowel preparation, preferably defined as Boston Bowel Preparation Scale score at least 2 in each of 3 colon segments or by description of the preparation as excellent, good, or adequate. The recommended screening or surveillance interval should be consistent with US Multi-Society Task Force recommendations.” | Strength of recommendation 1C; process measure; performance target at least 90 percent; priority indicator ACG/ASGE 2024, Table 3 and quality indicator 2 narrative · 2024-09 |
| Calderwood 2014 Numeric threshold | “A total BBPS score of at least 6 and/or all segment scores of at least 2 provides a standardized definition of “adequate for 10-year follow-up”.” | Cross-sectional observational analysis of 2,516 normal screening colonoscopies performed by 74 endoscopists at 36 practices in the Clinical Outcomes Research Initiative registry Calderwood 2014 · 2014-08 |
| Clark 2016 Numeric threshold | “Patients with BBPS scores of 2 or 3 for all colon segments have adequate bowel preparation for the detection of adenomas larger than 5 mm.” | Tandem colonoscopy study: 438 men, 1,161 colon segments, repeat examination within 60 days by a different blinded endoscopist. Adjusted proportion with missed adenomas larger than 5 mm was 5.2 percent for segments scored 2 versus 5.6 percent for segments scored 3, meeting a prespecified non-inferiority margin of 5 percent. Clark 2016 · 2016-02 |
| ESGE Numeric threshold | “ESGE states that standard guideline recommendations for surveillance intervals apply only to patients with adequate bowel preparation, defined as Boston Bowel Preparation Scale at least 6, Ottawa Scale at most 7, or Aronchick Scale excellent, good or fair.” | Stated as the adequacy premise attached to the ESGE post-polypectomy surveillance recommendations ESGE post-polypectomy surveillance guideline 2020, section on inadequate bowel preparation · 2020 |
| USMSTF 2020 Functional definition | “Adequate bowel preparation: bowel preparation adequate for visualization of polyps larger than 5 mm in size. The surveillance intervals in that document assume an examination complete to the caecum with an adequate preparation, performed by a colonoscopist with an adequate adenoma detection rate and attention to complete polyp excision.” | Definition table plus stated colonoscopy quality assumptions USMSTF 2020, Table 3 definitions and Colonoscopy quality assumptions · 2020-03 |
Each of three colon segments is scored 0 to 3 and the three segment scores are summed, so the total runs from 0 (unprepared colon) to 9. Segment scores are assigned after all cleansing manoeuvres are completed by the endoscopist. (Lai 2009, as of 2009-03).
| Score | Short form | Published wording |
|---|---|---|
| 0 | Unprepared | Unprepared colon segment with mucosa not seen because of solid stool that cannot be cleared. |
| 1 | Partly seen | Portion of mucosa of the colon segment seen, but other areas of the colon segment not well seen because of staining, residual stool and/or opaque liquid. |
| 2 | Seen well, minor residue | Minor amount of residual staining, small fragments of stool and/or opaque liquid, but mucosa of colon segment seen well. |
| 3 | Entirely seen | Entire mucosa of colon segment seen well with no residual staining, small fragments of stool or opaque liquid. |
| How well it holds up | Value | Source |
|---|---|---|
| Interobserver agreement, total score (development study, 633 colonoscopies, 22 clinicians) | Intraclass correlation coefficient 0.74 (95% predictive interval 0.67-0.80) | Lai 2009 · 2009-03 |
| Intraobserver agreement (development study) | Weighted kappa 0.77 | Lai 2009 as reported in Kastenberg 2018 · 2018-07 |
| Interrater reliability (comprehensive validation, 983 colonoscopies) | Intraclass correlation coefficient 0.91 | Calderwood 2010 · 2010-10 |
| Intrarater reliability (comprehensive validation) | Weighted kappa 0.78 (95% CI 0.73-0.84) | Calderwood 2010 · 2010-10 |
| Standing among competing scales | One large systematic review of various bowel preparation scales concluded that the Boston Bowel Preparation Scale was the most reliable and thoroughly validated. | USMSTF 2025, citing Kastenberg 2018 · 2025-04 |
| Why the guideline prefers it | Because it uses scores and explicit descriptions of what the scores mean, the Boston Bowel Preparation Scale is preferred. Further, the Boston Bowel Preparation Scale is specifically designed for use after completion of intraprocedural bowel cleaning, which is the most clinically relevant time point to assess cleansing quality. | ACG/ASGE 2024 · 2024-09 |
| Who | Recommendation | Grade |
|---|---|---|
| USMSTF 2025 | “We recommend a split-dose administration of bowel preparation purgatives for all patients, regardless of high-volume or low-volume preparation.” | Strong recommendation, high-quality evidence USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| USMSTF 2025 | “We recommend that a same-day regimen is an acceptable alternative to split dosing for individuals undergoing an afternoon colonoscopy.” | Strong recommendation, high-quality evidence USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| USMSTF 2025 | “We suggest that a same-day regimen is an inferior alternative to split dosing for individuals undergoing a morning colonoscopy.” | Weak recommendation, low-quality evidence USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| USMSTF 2025 | “For individuals using a split-dose regimen for colonoscopy preparation, we recommend the consumption of the second portion begin 4-6 hours before the time of colonoscopy and be completed at least 2 hours before the procedure start.” | Strong recommendation, moderate-quality evidence USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| ESGE 2019 | “ESGE recommends split-dose bowel preparation for elective colonoscopy.” | Strong recommendation, high quality evidence ESGE 2019, Main Recommendations · 2019-08 |
| ESGE 2019 | “ESGE recommends, for patients undergoing afternoon colonoscopy, a same-day bowel preparation as an acceptable alternative to split dosing.” | Strong recommendation, high quality evidence ESGE 2019, Main Recommendations · 2019-08 |
| ESGE 2019 | “ESGE recommends to start the last dose of bowel preparation within 5 hours of colonoscopy, and to complete it at least 2 hours before the beginning of the procedure.” | Strong recommendation, moderate quality evidence ESGE 2019, Main Recommendations · 2019-08 |
USMSTF 2025. Begin the second portion 4-6 hours before the time of colonoscopy and complete it at least 2 hours before the procedure start (strong recommendation, moderate-quality evidence).
ESGE 2019. Start the last dose within 5 hours of colonoscopy and complete it at least 2 hours before the beginning of the procedure (strong recommendation, moderate quality evidence).
Both set the same floor of at least 2 hours before the start. They differ at the far end: USMSTF names a 4-to-6-hour window for starting the second portion, ESGE caps the start at 5 hours. A start 5.5 to 6 hours out satisfies USMSTF and not ESGE. Neither figure is averaged here; both are shown as written.
| What was measured | Result as published | Source |
|---|---|---|
| Split-dose versus day-before, quality of cleansing | Odds ratio 2.51 (95 percent CI 1.86-3.39) for excellent or good cleansing, from 47 randomised trials and 13,487 patients | Martel 2015, reproduced in the ESGE 2019 text · 2015-07 |
| Same comparison restricted to polyethylene glycol | Odds ratio 2.60 (95 percent CI 1.46-4.63) | Martel 2015, reproduced in the ESGE 2019 text · 2015-07 |
| Same comparison restricted to sodium phosphate | Odds ratio 9.34 (95 percent CI 2.12-41.11) | Martel 2015, reproduced in the ESGE 2019 text · 2015-07 |
| Same comparison restricted to sodium picosulfate | Odds ratio 3.54 (95 percent CI 1.95-6.45) | Martel 2015, reproduced in the ESGE 2019 text · 2015-07 |
| Willingness to repeat the preparation | Odds ratio 1.90 (95 percent CI 1.05-3.46) favouring split-dose | Martel 2015, reproduced in the ESGE 2019 text · 2015-07 |
| Detection, split-dose versus day-prior 2 L PEG plus ascorbate (randomised trial) | Adenoma detection per colonoscopy 53.0 versus 40.9 percent; advanced adenoma detection per colonoscopy 26.4 versus 20.0 percent; adenomas per patient 1.15 versus 0.8 (p less than 0.001); advanced adenomas per patient 0.36 versus 0.22 (p less than 0.001) | USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| How fast the split-dose advantage decays with runway time | In a systematic review and meta-analysis of 29 randomised trials, the improvement from split dosing was maintained within 3 hours from the end of the purgative, progressively decreased after 4-5 hours, and was no longer present after 5 hours | USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| Every extra hour between last purgative and scope-in (non-split, day-prior regimens) | Associated with a 10 percent decrease in the likelihood of a good or excellent preparation | USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| Residual gastric fluid volume, split-dose versus day-prior (305 outpatients having EGD and colonoscopy, minimum 2-hour fast) | 11 mL versus 19 mL (p less than 0.001); pH 2 in both groups | USMSTF 2025, Dosing and Timing of Bowel Preparation Regimens · 2025-04 |
| Measure | Published finding | Source |
|---|---|---|
| Adenoma detection rate with an inadequate preparation | A systematic review and meta-analysis of 11 studies and more than 55,000 colonoscopies found a 5 percent absolute lower adenoma detection rate and a 1 to 2 percent absolute lower advanced adenoma detection rate with inadequate preparations compared with adequate or intermediate preparations. The odds ratio for detecting at least one adenoma, high-quality versus low-quality preparation, was 1.41 (95 percent CI 1.21-1.64). | Clark 2014, as reported in USMSTF 2025 · 2025-04 |
| Adenoma miss rate after an inadequate preparation | In a single-centre study of 3,047 patients with an inadequate preparation, among the 216 who returned and achieved an adequate preparation, 83 previously unseen adenomas were found – an adenoma miss rate of 42 percent (95 percent CI 35-49) and an advanced adenoma miss rate of 27 percent (95 percent CI 17-41). Restricted to colonoscopies repeated within 1 year, the adenoma and advanced adenoma miss rates were 35 and 36 percent. No cancers were missed in that study. | USMSTF 2025, Management of the Patient With an Inadequate and Nonsalvageable Bowel Preparation · 2025-04 |
| Yield of the repeat examination after a suboptimal preparation following a positive FIT | In 248 subjects with a positive faecal immunochemical test and a suboptimal preparation (BBPS segment score of 1 in at least one segment; segments scored 0 were excluded), the repeat colonoscopy at a mean of 352 days found an adenoma detection rate of 39 percent and an advanced adenoma detection rate of 15 percent. | USMSTF 2025, Management of the Patient With an Inadequate and Nonsalvageable Bowel Preparation · 2025-04 |
| How often the repeat is actually recommended | Among 260,314 screening or surveillance colonoscopies with inadequate bowel preparation in the GIQuIC registry, only 32 percent were accompanied by a recommendation to repeat the procedure within a year. That rose to 52 percent when advanced adenomas or serrated polyps were found and to 61 percent when the endoscopist failed to reach the caecum. | USMSTF 2025, Management of the Patient With an Inadequate and Nonsalvageable Bowel Preparation · 2025-04 |
| Missed lesions when cleansing is inadequate | A prospective observational study with repeat colonoscopy by a blinded endoscopist revealed a threefold higher miss rate for adenomas at least 5 mm in size when bowel cleansing was inadequate. | ESGE 2019, Introduction · 2019-08 |
| Segment-level signal, and its limit | Among segment pairs without polyps at the first colonoscopy (n = 601), segments with inadequate BBPS scores had a higher polyp detection rate at the second colonoscopy (10 versus 5 percent, p = 0.04); among segment pairs with polyps at the first colonoscopy (n = 154), advanced polyp detection at the second was 20 versus 4 percent (p = 0.03). In multivariable analysis, however, it was the presence of advanced polyps at the initial colonoscopy (adjusted odds ratio 3.5, 95 percent CI 1.1-10.8) and not an inadequate BBPS score (adjusted odds ratio 1.8, 95 percent CI 0.6-5.1) that independently predicted advanced polyps at the second examination. | Kluge 2018 · 2018-03 |
| Who | Target | Statement |
|---|---|---|
| USMSTF 2025 | 90% | “We recommend an endoscopy unit-level and individual endoscopist-level bowel preparation adequacy rate of at least 90 percent.” Strong recommendation, moderate-quality evidence · USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04 |
| USMSTF 2025 | — | “We recommend routine tracking of the rate of adequate bowel preparations at the level of individual endoscopists and at the level of the endoscopy unit.” Strong recommendation, moderate-quality evidence · USMSTF 2025, Bowel Preparation Adequacy Rate as a Quality Measure · as of 2025-04 |
| ACG/ASGE 2024 | 90% | “Rate of bowel preparation adequacy is a priority quality indicator with a performance target of at least 90 percent, measure type process, strength of recommendation 1C. To count toward meeting the 90 percent compliance target, the recommended follow-up interval must be consistent with US MSTF post-polypectomy or post-cancer resection surveillance recommendations.” 1C, process measure, priority indicator · ACG/ASGE 2024, Table 3 and quality indicator 2 · as of 2024-09 |
| ESGE | 90% | “A minimum standard of at least 90 percent for adequate bowel preparation, assessed using validated scales, has been recommended by the Quality Committee of the European Society of Gastrointestinal Endoscopy.” ESGE performance measure, quoted in the ESGE 2019 introduction · ESGE 2019, Introduction · as of 2019-08 |
| USMSTF 2014 (superseded) | 85% | “The US MSTF recommended in 2014 that at least 85 percent of outpatient colonoscopies should be accompanied by an adequate bowel preparation.” Superseded by the 90 percent target in ACG/ASGE 2024 and USMSTF 2025 · ACG/ASGE 2024, Rate of bowel preparation adequacy · as of 2014 |
Representative odds ratio selected among the references cited by the guideline. The magnitudes are reproduced exactly as published.
| Risk factor | Odds ratio | 95% CI |
|---|---|---|
| Cirrhosis | 3.4 | 1.5–7.9 |
| Parkinson disease | 3.2 | 1.2–9.3 |
| Dementia | 3.0 | 1.2–7.5 |
| Tricyclic antidepressant use | 2.0 | 1.4–2.9 |
| Diabetes | 1.8 | 1.5–2.1 |
| Opioid use | 1.7 | 1.4–2.1 |
| Gastroparesis | 1.6 | 1.2–2.3 |
| Previous colorectal surgery | 1.6 | 1.2–2.2 |
| Lower level of education | 1.5 | 1.3–1.8 |
| Body mass index above 30 kg/m2 | 1.5 | 1.2–1.8 |
| Inpatient status | 1.5 | 1.1–2.1 |
| Hypertension | 1.3 | 1.2–1.4 |
| Tobacco use | 1.3 | 1.1–1.5 |
| Constipation | 1.3 | 1.0–1.6 |
| Medicaid versus private insurance | 1.3 | 1.1–1.6 |
| Medicare versus private insurance | 1.2 | 1.1–1.3 |
| Male sex | 1.2 | 1.1–1.3 |
| Age above 65 | 1.1 | 1.1–1.2 |
| Body mass index, each unit | 1.1 | 1.0–1.1 |
Rule. Every score definition, threshold, interval, strength rating, benchmark and effect estimate in this file is copied from the named source. Nothing is estimated, averaged, interpolated or carried across from a similar entity. Where two authorities word the same rule differently, both are stored and both are shown attributed rather than reconciled. No drug dose appears unless the cited guideline itself states that dose, and where it does the recommendation grade travels with it.
Provenance. The published Gastroenterology and Gastrointestinal Endoscopy full texts of the 2025 USMSTF bowel preparation recommendations return HTTP 403 to automated fetching. The identical article text was read from the society-distributed PDF reprint (AGA Section, Gastroenterology April 2025, pages 798-829); page furniture in that PDF confirms the journal, volume, issue and page range. The 2024 ACG/ASGE quality indicators were read from the GIQuIC-hosted PDF of the American Journal of Gastroenterology article of record. Text extracted from the 2025 USMSTF and 2024 ACG/ASGE PDFs loses the greater-than-or-equal and less-than-or-equal glyphs in a few places. Where the surrounding sentence makes the relation unambiguous (for example an adequacy rate ‘of 90%’ in a sentence whose recommendation heading reads ‘of at least 90%’) the relation has been restored as ‘at least’. No numeric value was altered.
Built. 2026-08-01. Re-verify by. 2027-08-01. Re-verify at least annually, and immediately whenever the USMSTF revises its bowel preparation recommendations, the ACG/ASGE Quality Task Force revises the colonoscopy quality indicators, or ESGE updates its bowel preparation guideline.
| Key | Citation | As of / access |
|---|---|---|
| USMSTF 2025 | Jacobson BC, Anderson JC, Burke CA, Dominitz JA, Gross SA, May FP, Patel SG, Shaukat A, Robertson DJ. Gastroenterology 2025;168(4):798-829. doi 10.1053/j.gastro.2025.02.002 Published simultaneously as Gastrointest Endosc 2025;101(4):702-732, doi 10.1016/j.gie.2025.02.010. | 2025-04 Full PDF reprint read |
| ACG/ASGE 2024 | Rex DK, Anderson JC, Butterly LF, Day LW, Dominitz JA, Kaltenbach T, Ladabaum U, Levin TR, Shaukat A, Achkar JP, Farraye FA, Kane SV, Shaheen NJ. Am J Gastroenterol 2024;119(9):1754-1780. doi 10.14309/ajg.0000000000002972 Published simultaneously in Gastrointestinal Endoscopy 2024;100(3):352-381. | 2024-09 Full PDF read |
| ESGE 2019 | Hassan C, East J, Radaelli F, Spada C, Benamouzig R, Bisschops R, Bretthauer M, Dekker E, Dinis-Ribeiro M, Ferlitsch M, Fuccio L, Awadie H, Gralnek I, Jover R, Kaminski MF, Pellise M, Triantafyllou K, Vanella G, Mangas-Sanjuan C, Frazzoni L, van Hooft JE, Dumonceau JM. Endoscopy 2019;51(8):775-794. doi 10.1055/a-0959-0505 | 2019-08 Full ESGE-hosted PDF read |
| USMSTF 2020 | Gupta S, Lieberman D, Anderson JC, Burke CA, Dominitz JA, Kaltenbach T, Robertson DJ, Shaukat A, Syngal S, Rex DK. Gastrointest Endosc 2020;91(3):463-485. Published simultaneously in Gastroenterology 2020;158(4):1131-1153. | 2020-03 Full ASGE-hosted PDF read |
| Lai 2009 | Lai EJ, Calderwood AH, Doros G, Fix OK, Jacobson BC. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc 2009;69(3 Pt 2):620-625. | 2009-03 PubMed Central full text (PMC2763922) |
| Calderwood 2010 | Calderwood AH, Jacobson BC. Comprehensive validation of the Boston Bowel Preparation Scale. Gastrointest Endosc 2010;72(4):686-692. PMID 20883845. | 2010-10 Publisher abstract of record |
| Calderwood 2014 | Calderwood AH, Schroy PC 3rd, Lieberman DA, Logan JR, Zurfluh M, Jacobson BC. Boston Bowel Preparation Scale scores provide a standardized definition of adequate for describing bowel cleanliness. Gastrointest Endosc 2014;80(2):269-276. PMID 24629422. | 2014-08 PubMed Central full text (PMC4104141) |
| Clark 2016 | Clark BT, Protiva P, Nagar A, Imaeda A, Ciarleglio MM, Deng Y, Laine L. Quantification of Adequate Bowel Preparation for Screening or Surveillance Colonoscopy in Men. Gastroenterology 2016;150(2):396-405. | 2016-02 Publisher abstract of record; the 2025 USMSTF document describes this study and its conclusion in its own words, which are quoted here |
| Clark 2014 | Clark BT, Rustagi T, Laine L. What level of bowel prep quality requires early repeat colonoscopy: systematic review and meta-analysis of the impact of preparation quality on adenoma detection rate. Am J Gastroenterol 2014;109(11):1714-1723. | 2014-11 Effect estimates quoted as reported inside the 2025 USMSTF document (reference 193) |
| Kluge 2018 | Kluge MA, Williams JL, Wu CK, Jacobson BC, Schroy PC 3rd, Lieberman DA, Calderwood AH. Inadequate Boston Bowel Preparation Scale scores predict the risk of missed neoplasia on the next colonoscopy. Gastrointest Endosc 2018;87(3):744-751. PMID 28648575. | 2018-03 Publisher abstract of record |
| Martel 2015 | Martel M, Barkun AN, Menard C, Restellini S, Kherad O, Vanasse A. Split-Dose Preparations Are Superior to Day-Before Bowel Cleansing Regimens: A Meta-analysis. Gastroenterology 2015;149(1):79-88. PMID 25863216. doi 10.1053/j.gastro.2015.04.004 | 2015-07 Full abstract of record read; the same effect estimates are reproduced inside the ESGE 2019 PDF (reference 55), which was read directly |
| Kim 2024 | Kim J, Choi JM, Lee J, Han YM, Jin EH, Lim JH, Bae JH, Seo JY. Boston bowel preparation scale score 6 has more missed lesions compared with 7-9. Sci Rep 2024;14:1605. doi 10.1038/s41598-024-52244-8 | 2024-01 PubMed Central full text (PMC10796329) |
| Kastenberg 2018 | Kastenberg D, Bertiger G, Brogadir S. Bowel preparation quality scales for colonoscopy. World J Gastroenterol 2018;24(26):2833-2843. doi 10.3748/wjg.v24.i26.2833 | 2018-07 PubMed Central full text (PMC6048432) |